Iontec It-389

Iontech Ionizer Understands your Alkaline Water Ionizers

Price : 350 K.D

Energize your mind, body, heart and soul with the Award Winning Alkaline Water Ionizers from the World’s leading manufacturer

Automatic 10 second electrolysis chamber cleansing after each Alkaline water use.

The strongest water cleaning technology

Records Alkaline water production volume and automatically cleans when production reaches 50 liters.


What’s the difference between a water purifier and water ionizer? 

Water purifier is usually a basic device for home use that filters chemicals and impurities. Purifiers are unable to change the pH values, ORP values or the structure of water molecules. A water ionizer uses electrolysis to alter water pH and ORP values and molecular cluster structures of the water. It conditions the water chemistry for the user. The pH value of the output can be selected for different uses; drinking, cooking, washing, healing, etc.

Industry leading USA manufacturing technique complies with the highest drinking water standards

Higher absorption efficiency than coconut-shell granular carbon, is able to absorb very fine impurities, chemicals, such as chlorine, agriculture pesticides, etc.

7 selectable levels of water pH values

Elegant & Easier to view in bright conditions light.

7 levels of water pH: 4 levels of Alkaline water, 1 level of Neutral water and 2 levels of Acid water.

Displays pH, ORP, water flow rate, filter life and working status.

Platinum-titanium electrolysis plate &ion membrane-manufactured in Japan

High-tech platinum-titanium electrolysis plate manufactured by KOBE Steel, Japan.

Ceramic ion membrane manufactured by Yuasa, Japan, temperature-resistant and non-toxic.

Product Specifications

ModelIT-636IT-656
Electrolysis Plate MaterialPlatinum-titanium plate; manufactured by KOBE Steel, Japan
Q’ty of Electrolysis Plates3 plates5 plates
VoltageAC100V / AC220V, 50/60HZ
Power ConsumptionMax. 180WMax. 230W
Inlet Water Pressure0.9~5.0 kg/cm2
Electrolysis MethodContinuous electrolysis (built-in flow meter)
Water Flow Rate

Ideal water processing : 2 Liters/min. (based on inlet water pressure 1kgf/cm2)

Water flow rate : 3 Liters/min. (based on inlet water pressure 2kgf/cm2)

DisplaypH, O.R.P, water flow rate, working status, clean, pure, alkaline, acidity and filter service life
Cleaning10 second automatic cleansing after each alkaline water use*
manual cleansing option if Alkaline water consumption is below 30 liters
Electrolysis Levels4 Alkaline levels, 1 Neutral level and 2 Acidic levels
pH AdjustmentEach electrolysis level gives 20 segments for pH adjustment(based on source water quality in different areas)
Filter MaterialActivated carbon fiber (ACF), manufactured in USA
Filter Service LifeApprox. 12,000 liters (depends on source water quality)
Safety Protection DeviceCurrent protection & Alarm only if drinking Acidic water
Dimension & WeightDimension: H 310mm x W 220mm x D 125mm (Approx.) Weight: 4.0 kgs (Approx.)
pH Value (based on source water quality)5~104.5~11
O.R.P Value (based on source water quality)-650mv (Max.)-850mv (Max.)

Iontech Ionizer

A water ionizer electrolyzes water with direct current voltage (DCV). A special attachment re-directs tap water out of the faucet through a plastic hose into the ionizer unit. Inside, the water is first filtered through activated charcoal.

Each ionizer unit has a specially engineered electrolysis chamber equipped with platinum-coated titanium electrolysis plates.The filtered water flows into the chamber and is directed through a ceramic membrane that is positioned between the charged electrolysis plates.

The conditioned or ‘Ionized’ water then exits through two ports (an alkaline port and an acidic port).Cations are attracted to the negatively charged plate to produce cathodic water (reduced water).Anions, negatively charged ions, are attracted to the positively charged plate to produce anodic water (oxidized water).

The (-) cathode attracts minerals such as sodium, magnesium, potassium, calcium and others and the water surrounding the terminal becomes alkaline with an increase in hydrogen ions (H+). The anti-cathode terminal attracts ions such as oxygen, sulfuric acid, sulfur and the water surrounding the terminal becomes acidic with an increase in hydroxide ions (OH-).

The conditioned or ‘Ionized’ water then exits through two ports (an alkaline port and an acidic port).Cations are attracted to the negatively charged plate to produce cathodic water (reduced water).Anions, negatively charged ions, are attracted to the positively charged plate to produce anodic water (oxidized water).

The (-) cathode attracts minerals such as sodium, magnesium, potassium, calcium and others and the water surrounding the terminal becomes alkaline with an increase in hydrogen ions (H+). The anti-cathode terminal attracts ions such as oxygen, sulfuric acid, sulfur and the water surrounding the terminal becomes acidic with an increase in hydroxide ions (OH-).

The water discharged from the alkaline port has a higher pH value and contains minerals, like Calcium and Magnesium, that are in a form that is more suitable for the body to assimilate.

Calcium, Potassium, Magnesium and other minerals can normally be found in drinking water. But these minerals in are complex,inorganic and very stable. These are not easily assimilated by the body. However, minerals in ionized water are separated into ions with (-)ORP. These ions unite with the acidic residues with positive ions. They act as buffering agents that are easily assimilated and eliminated by our bodies.

Shopping Cart